AMT 19
Released: 06 Jun 2017.
For availability, please contact the Avanade Service Portal for information on downloading new releases.
Special attention items:
There are no special attention items for this release.
Product | Cat | Subcat | Description | Type | Version | Priority |
---|---|---|---|---|---|---|
Runtime | Various | C1703-023 DB2 on Windows or Linux is now supported. | AMT 19 | |||
Developer | Revision Control | 324018 The 'Show Differences' screen didn't show the code window by default for Classes, this is the case now. In the Revision screen under history, when opening the show difference window the default window was 'options'. Now the default opened window is 'code' when showing differences for classes. | AMT 19 | |||
Developer | Revision Control | 314762 Added new filter States in "Revision Control Screen". The request was to also have a new state to choose in the revision control screen in the state drop down. This has been solved by adding a "Only New" state, this filter shows every item that isn't in the current generation set minus the deleted items. Because the information was already available and could easily be output the "Only Deleted" and "Only Not Locked" states have also been added as a filter. | AMT 19 | |||
Control Center | Configuration | 307194 New Option to test Database connection in the Control Center When adding a new database in the Control Center, a new button has been added that allows the administrator to test if the settings to access the database are correct. | AMT 19 | |||
Developer | Various | 323643 When an item is undocked(floating) the corresponding caption is placed in the title bar and returned to the standard short title version when re-docked. Working with multiple monitors and having several versions of a single file open to reference another version was complicated because there where no indicators if the right version was being edited. When an item is undocked(floating) the corresponding caption is placed in the title bar and returned to the standard short title version when re-docked. | AMT 19 | |||
Developer | Database | 324373 Calling a remote stored procedure on a different mssql server. Calling a remote stored procedure on a different msssql server did not function correctly. The usage of prefix setting of mssql database setting is corrected for stored procedure calls. If prefix of stored procedure is not filled it will apply prefix configured within database settings. | AMT 19 | |||
Runtime | Scripts | C1705-022 FTP (AmtFtp object) functionality is now added to the ComScript.dll interface. Supporting: -FTP or FTP/SSL (Explicit) -BINARY or TEXT file transfer -Passive or Active transfer mode | AMT 19 | |||
Runtime | Web Client | 325420 ACTRI - OPERATOR FIELD CAUSES ERROR In the Web Client submitting a form containing a password field with Uppercase property set to true would result in a session transmit error. In the latest version submitting a form containing a password field with Uppercase property set to true behaves correctly. | AMT 19 | |||
Runtime | LionScreens | 324110 Provided Webservice not in statistics In statistics overview, it was not entirely clear when a call from a provided webservice was made. Now, when a call comes from a provided webservice, it is visible by (PW) after the form name. (DM) calls from Display_Main, (PM) calls from Process_Main and (EV) calls from screen events where already visible. | AMT 19 | |||
Generator | Various | C1705-050 ProdInstaller crashed when using Roslyn ProdInstaller crashed when using the Roslyn preview to generate the programs. The file property didn't had values for the description/version etc (as shown in the file explorer details on a file). This has been resolved. | AMT 19 | |||
Developer | Database | 325446 Editing stored procedures in the IDE caused invalid direction on the parameters. Editing stored procedures parameters in the IDE caused invalid direction on the parameters. Corrected. Now the editing works again. Any wrong editing needs to be corrected. But the generator should highlight them during generation. | AMT 19 | |||
Runtime | Web Client | 325396 Phantom spinner is shown long after data returned when using Internet Explorer 11 Using Internet Explorer 11 upon submitting a form, the mouse cursor sometimes continued to spin although the page had already rendered. This created the illusion that the page or data is still loading. The mouse cursor is now correctly reset to default after a form submit is done. | AMT 19 | |||
Runtime | Web Client | 325435 Dynamic form in the web wrong with lineheight. The line height property was ignored in the web. Corrected implementation and now its using the defined value in Amt and not the 20 pixels. | AMT 19 | |||
Runtime | Jobs/Batches | C1705-059 There is a new property on the AmtSort in Comscript called DeleteDuplicateRecords (Boolean) When the property is set to true, all duplicate keys in the sort file will be removed. | AMT 19 | |||
Runtime | Various | C1705-067 In previous versions of AMT the AMtPrintController (and runtime library functions) removed all HEX00 and HEX01 characters from the print data. For some customers this behavior was unwanted. And therefore we have added a new option "Hex value printing filter" to the runtime behavior settings in the AMT Control Center. Depending on the selected filter option(s) the AmtPrintController will remove (or keep) HEX00 and HEX01 characters from the print data. | AMT 19 |