AMT 181
Released: 20 Nov 2026.
For availability, please contact the Avanade Service Portal for information on downloading new releases.
Special attention items:
AMT 181
Warning:
- AMT 181 has a known issue with COBOL applications that use VSAM files with alternate indexes migrated to SQLite. If your application uses this configuration, contact AMT Customer Support before you upgrade.
| Product | Cat | Subcat | Description | Type | Version | Priority |
|---|---|---|---|---|---|---|
| AMT LION | AMT COBOL | AMT Product Suite | Security | #109036
New secure-storage AES keys were derived using PBKDF2 with SHA-1 and a low iteration count, which did not meet current security requirements. We updated key creation to use PBKDF2 with SHA-256 and 600,000 iterations. Existing encrypted data remains compatible and does not need to be re-encrypted. |
CHANGE | AMT 181 | HIGH |
| AMT LION | Runtime | AMT Screens | #109808
INC: 1432495 Disabled Editbox, MaskEditBox, Memo, ComboBox, CheckBox, and RadioButton controls controls in AMT Screens did not visually match the standard appearance of disabled controls in WPF applications. We aligned the styling of disabled graphical controls with native WPF, providing a more consistent visual experience. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | Runtime | Blazor Web Client | #113612
INC: 1507557 In the Blazor Web Client, the Ctrl+P, Ctrl+L, and Ctrl+Shift+I keyboard shortcuts were not recognized, preventing users from performing the associated actions. We corrected the keyboard shortcut handling so that Ctrl+P, Ctrl+L, and Ctrl+Shift+I now work as intended. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #114816
When a COBOL COPY statement appeared inside an IF or PERFORM block, its terminating period could incorrectly close the surrounding scope. This could leave END-IF or END-PERFORM unmatched and cause valid COBOL programs to fail conversion. We updated the COBOL parser to keep explicitly delimited IF and PERFORM scopes open when processing periods introduced by copied source. The scope now remains active until its corresponding END-IF or END-PERFORM is reached. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | Runtime | Blazor Web Client | #117317
In the Blazor Web Client, when users worked with forms that exceeded the browser width, the horizontal scroll position could jump back to the left when focus changed or was restored. We updated focus handling to preserve the horizontal scroll position when restoring focus to ComboBoxes and other controls. |
FIX | AMT 181 | MEDIUM |
| AMT LION | Runtime | Blazor Web Client | #117352
INC: 1538518 In the Blazor Web Client, the entries of a combo box with the style set to Simple were displayed outside the combo box. We corrected the rendering of Simple style combo boxes so that the item list is now hidden, as in AMT Screens. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #117394
In AMT COBOL, when a Report Writer report group contained a named SUM counter without a COLUMN clause, the Generator didn't create the counter in the generated print definitions. Procedure Division code that referenced the counter, such as a USE BEFORE REPORTING declarative, then failed to compile. We updated the generator so that named SUM counters without a COLUMN clause are now generated as data items with their PIC length. Affected reports now build successfully and calculate their totals correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #117434
In AMT COBOL applications converted from OS2200, an RDMS DELETE statement that uses the extended ALL form, such as DELETE table ALL, generated SQL that SQL Server rejected. We updated the generator so that DELETE ... ALL [ROWS] and UPDATE ... ALL [ROWS] now generate valid SQL Server statements that affect every row of the table. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #117435
In AMT COBOL applications converted from OS2200, some embedded SQL searches failed when the LIKE pattern was a host variable written without the leading colon. The converter treated the variable name as column names, so SQL Server reported an invalid column name. We updated the parser so that a hyphenated host variable without a colon in a LIKE operand is now recognized and passed as a parameter, just like a colon-prefixed host variable. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #117438
In AMT COBOL programs, using CURRENT_TIME(n) or CURRENT_TIMESTAMP(n) SQL functions with a precision value generated a statement that SQL Server rejected. We updated the SQL generation to drop the precision value. The statements now run, and SQL Server stores the value with the precision of the target column. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #117440
In AMT COBOL applications that target SQL Server, queries that compared multiple columns against a subquery, such as (col1, col2) IN (SELECT ...), failed to run. SQL Server doesn't support this form and reported a non-boolean expression error. The NOT IN form failed in the same way. We updated the SQL generation to rewrite these predicates into an equivalent EXISTS or NOT EXISTS form when the target is SQL Server. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #117442
Some AMT COBOL SQL queries that joined several tables failed because the generated SQL did not clearly identify which table a shared column belonged to. We updated the generator to qualify shared column names with the correct table. Affected queries now run correctly after generation. |
FIX | AMT 181 | MEDIUM |
| AMT LION | Generator | Various | #117529
INC: 1505210 In AMT LION forms, a FileUploader control placed inside a GroupBox was hidden in the Blazor Web Client because it wasn't given a valid z-order. We corrected the generation so that the z-order of a FileUploader control is now included in the generated form definition. FileUploader controls now appear in the correct stacking order. You must regenerate the affected forms. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #117539
In AMT COBOL applications converted from OS2200 DPS, after users entered data on specific converted screens, the application did not continue to the next detail screen as it did on the mainframe. We updated the runtime to correctly recognize fields that are open for input. Affected screens now continue to the next detail screen as intended. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AmtTools | Various | #117558
The ComScript FileObject interface was extended with a function to support the WFL COPY option SKIPEXCLUSIVE. |
NEW | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AmtTools | Reo | #117661
We added a KEEPSYSNONYMS option to AmtReoConsole, the command-line-only database reorganization tool. The option retains any synonyms that are no longer in the schema after reorganization. |
NEW | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #117707
A COBOL START statement using the GREATER condition could fail because the key was not passed correctly during the operation. We corrected the key handling for START operations using GREATER, allowing affected indexed-file operations to execute correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | AmtTools | Transaction Server | #118000
In merged AMT LION and AMT COBOL applications used through the Blazor Web Client, a COBOL OS2200 screen that stored a DPS page and then passed control to a LION form in the same step failed with the message "Transaction number is invalid. Possible double transmit." We updated the runtime so that the current DPS page number of COBOL screens is now kept separately from the session information that LION forms use. The LION form now opens normally after a COBOL screen stores a page. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Configuration | #118013
We added a generation set option for COBOL IBM applications to allow processing to continue after a DivideByZero exception. |
NEW | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #118112
Some COBOL BMS attributes were not processed correctly, causing affected screens or fields to behave or display incorrectly. We corrected the handling of several BMS attributes so they are now processed as intended. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AmtTools | Various | #118290
The ComScript sort interface used by JCL PowerShell scripts did not support INREC/OUTREC EDIT functionality, preventing affected scripts from being processed correctly. We added partial support for INREC/OUTREC EDIT in the ComScript sort interface used by JCL PowerShell scripts. |
NEW | AMT 181 | MEDIUM |
| AMT LION | Generator | Various | #118318
AMT Lion generated insertables did not compile when a global insertable used identically named variables belonging to different structures. We updated the generator to create a separate parameter for each variable based on its structure. The generated Insertables now compiles correctly when duplicate variable names occur in different structures. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #118365
In AMT COBOL, some DB2 date and time formats were not handled correctly, which could cause issues when applications processed these values. We extended DB2 date and time handling to support additional formats, allowing affected values to be processed correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #118416
Some COBOL report writer programs displayed blank or incorrect totals because report preparation occurred before the current totals were available. We corrected the report writer processing sequence so that preparation occurs after the current totals are available. Affected reports now print the correct totals. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AmtTools | Various | #118512
We extended the ComScript Sort interface to support additional JCL SORT options, including JOINKEYS and OUTFIL options. |
NEW | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #118533
In AMT COBOL applications, opening a cursor failed when the cursor's static DECLARE CURSOR statement was in a paragraph that the program never performed. We updated the Generator so that static cursors are now available throughout the program, regardless of where they're declared. Cursors that are declared more than once, declared for a prepared statement, or declared in WORKING-STORAGE or copybooks keep their previous behavior. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118534
Some AMT COBOL migrated queries that selected all columns from several tables generated SQL that SQL Server could not process because the column references were not sufficiently qualified. We updated the parser to generate the requested columns explicitly and qualify each column with its corresponding table. Affected queries now run correctly on SQL Server. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118535
An AMT COBOL, migrated query could fail in SQL Server when the same column appeared multiple times in the result and was also used for sorting. We updated the parser to qualify the sort column with its source table. Affected queries now run correctly in SQL Server. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118541
A-Series COBOL programs using 01 name INVOKE set-name could fail during generation. The conversion could also incorrectly create an empty database table named after the DMSII set. We updated the parser to recognize the set name as an access path to the DMSII set. Affected programs now generate correctly, and the conversion no longer creates an unnecessary empty table. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118556
Some converted COBOL programs incorrectly evaluated conditions against true or false, causing them to follow the wrong processing path. We corrected the condition evaluation to match the original mainframe behavior. Affected programs now follow the correct processing path and save changes as intended. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #118606
In AMT COBOL, some OS2200 DPS screens displayed labels, even when the program had switched off the corresponding screen area. We updated DPS dynamic screen handling so that screen areas switched off by the program, including nested areas and their text and fields, are fully blank, matching the original mainframe behavior. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | Runtime | Various | #118619
In the Blazor Web Client and AMT Screens, numeric fields with DecimalChar = Default could display values without a decimal separator. For example, 100.00 could appear as 10000, and repeatedly leaving the field could add extra trailing zeros. We updated the default decimal separator to a period (.), or a comma (,) when the thousands separator is a period. Fields with an explicitly configured decimal separator remain unchanged. |
FIX | AMT 181 | MEDIUM |
| AMT LION | Developer | Code Logic | #118634
Lion code that used a numeric value with decimal places as a table position could not be generated. We updated the parser to use the whole-number part of the value as the table position. Affected programs now generate correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118705
In COBOL OS2200 applications that access RDMS through the interpreter interface (ACOB$RDMR) some programs could not be built because the parser did not recognize a DROP CURSOR statement. As a result, screens that relied on these programs displayed an empty page instead of the requested data. We updated the parser to recognize and process the DROP CURSOR statement. Affected programs now build successfully, and their screens display the requested data. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #118706
In COBOL OS2200 applications that access RDMS through the interpreter interface (ACOB$RDMR), programs that moved an RDMS command literal to the whole command buffer, instead of line by line, couldn't be generated. Generation failed with the error "Word RDMS not understood". We updated the parser so that a command literal moved to the whole command buffer is now read in the same way as a command built line by line. These programs now generate. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #119223
In converted COBOL programs, when a procedure division copybook used GO TO to jump to a paragraph of the program that included it, the program continued with the paragraphs after the COPY statement instead of at the jump target. We updated the parser and the Generator so that the program now continues at the GO TO target after such a copybook, as on the source system. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #119392
SQLite indexes of converted VSAM files, could contain duplicate entries because COMP key fields involving REDEFINES were not mapped correctly. We updated the SQLite index handling to use the binary representation of COMP key fields instead of their numeric value. This ensures the index keys are represented correctly and prevents duplicate entries. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #119404
In AMT COBOL, switchable areas on some OS2200 DPS screens could extend beyond their intended space, covering labels and input fields. We corrected the layout handling so that switchable screen areas occupy only their intended space, matching the original mainframe behavior. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Blazor Web Client | #119417
Empty COBOL OS2200 DPS numeric input fields were displayed as blank boxes in the Blazor Web Client, instead of showing underscores. We updated the field display so that empty numeric input fields are now filled with underscores, consistent with the mainframe behavior. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | Runtime | Blazor Web Client | #119422
In the Blazor Web Client, after reloading the page or reopening the browser, users could sometimes encounter an error page instead of returning to their application. We updated the sign-in handling to renew the user session automatically when appropriate. Users can now reload or reopen the browser without interruption and are prompted to sign in again only after their session has ended. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Runtime | Various | #119465
In AMT COBOL, fields on OS2200 DPS screens that the program had hidden or made read-only could become visible or editable when their containing screen area was shown. We updated DPS screen handling so that individual fields retain their hidden or read-only settings when the surrounding screen area is displayed, matching the original mainframe behavior. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | AmtTools | Reo | #119628
In AMT COBOL OS2200 applications, queries using the RDMS LPAD() function failed because the required database helper function was not available for the reoganize application. We updated AMT Reoganize to create the required helper function in the database for affected applications. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Generator | Various | #119631
In COBOL OS2200 applications on SQL Server, embedded SQL statements that stored the result of the RDMS RUN_ID() function in a 6-character column failed with the error "String or binary data would be truncated." We updated the generator so that RUN_ID() in embedded SQL now returns at most 6 characters, as in RDMS and as already done for routines and triggers. This also applies when the value is selected into a longer host variable. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #119633
In AMT COBOL OS2200 applications, some multi-line database commands were joined without the required spacing, causing words to run together and resulting in invalid commands. We corrected the line-joining logic to preserve the required separation between words, matching the original mainframe behavior. The affected database commands are now generated correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #119634
In AMT COBOL OS2200 applications, queries that performed a self join could contain ambiguous column references, causing the program to stop with a database error. We updated the conversion to associate each column with the correct table reference automatically. Affected queries now run correctly. |
FIX | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #119699
IBM COBOL AFP-5A print functionality was not previously supported in AMT COBOL. We added AFP-5A print support, enabling applications that use this print format to process their print output. |
NEW | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AmtTools | Various | #119818
The ComScript sort interface used by JCL PowerShell scripts did not support all required SORT commands, preventing affected scripts from being processed correctly. We added support for additional SORT commands in the ComScript sort interface used by JCL PowerShell scripts. See the ComScript sort interface help page for the supported commands. |
NEW | AMT 181 | MEDIUM |
| AMT COBOL | Developer | Code Logic | #120032
In AMT COBOL, When a copybook was included again with a replacement such as STPD to NEW, the converter could leave names such as STPD-RECORD-KEY unchanged instead of converting them to NEW-RECORD-KEY. We corrected the COPY replacement logic to handle hyphenated COBOL names correctly. Replacement operands are now applied as intended when they form part of a hyphenated data name. |
FIX | AMT 181 | MEDIUM |
| AMT LION | AMT COBOL | AMT Product Suite | Security | #120207
A high-severity security vulnerability (GHSA-x33c-w48q-qrgc) in Microsoft.AspNetCore.WebUtilities version 10.0.13 prevented builds and deliveries from proceeding. We updated Microsoft.AspNetCore.WebUtilities to the patched version 10.0.15, resolving the identified security vulnerability. |
FIX | AMT 181 | HIGH |
